Digital Tube Display; Display Of Decimal Data; Binary Data Display; Parameter Attribute Identification - Danfoss VFD500 Series Manual

Table of Contents

Advertisement

Chapter 4 Operation and display

4.3 Digital tube display

Display of decimal data

16 digits:
The range of unsigned numbers is 0 ~ 65535 (without decimal point). The displayed range of signed numbers
is -9999 ~ 32767 (excluding decimal point). The negative numbers less than -9999 will be displayed as -9999.
32 digits:
The left and right screen display, combined with the following figure to illustrate:
Dot1 is used to distinguish between the left and right screens. On indicates the left panel (upper 5 digits) and turns
off the right screen (lower 5 digits). When the left screen is displayed, Dot5 is used to indicate the sign digit. On
indicates that the value is negative, off indicates the value is Positive.
The display range of 32-bit unsigned numbers is 0 to 4294967295 (excluding decimal point), and the displayed
range of signed numbers is -2147483648 to 2147483647 (excluding the decimal point).

Binary data display

Binary number currently only supports 16 digits, points left and right screen display.
The leftmost digital tube is used to distinguish the left and right screens: the top digit segment lights up for the left
panel and the bottom segment segment lights for the right panel.
Remove the leftmost digital tube, from right to left, followed by Bit0 ~ Bit15. The upper segment is lit to indicate 1,
the lower segment to light to indicate 0.!

Parameter attribute identification

Editable parameters The leftmost LED displays "P"; the leftmost LED of the read-only parameter displays "r", as
shown below.
Specific symbol
In some cases, the digital tube will display a specific symbol. The meaning of specific symbols is shown in the
following table:Table4-2 Digital tube display symbol and meaning
VFD500 high performance vector control frequency inverter user manual
!
Dot5
Means left screen ,high 8bit
bit15=0
P means can edit
!
R means read only
Symbol
tUnE
Motor parameter self-learning
bUSY
Processing parameter read and write requests
• Indicates that the parameters have been changed
End
and saved to the EEPROM
• The mission has been completed
• Fault code, "XXX" is the fault type, see Chapter 6 for
Er.xxx
details
38
Dot1
Means right
screen ,low 5bit
Meaning
bit1=1
bit0=0

Advertisement