VFD500 high performance vector control frequency inverter user manual
Fault protection action
P23.18
selection 1
Fault protection action
P23.19
selection 2
Fault protection action
P23.20
selection 3
Fault protection action
P23.21
selection 4
P23.24
Fault reset
Unit's digit : input phase loss

0: coast to stop

1: Emergent stop 

2: Stop as per stop mode

3: Continue to Run

Ten'unit: user self-defined fault 1

same as Unit's digit

Hundred'unit: user self-defined fault 2

same as Unit'digit

Thousand's unit: communication fault

same as unit's digit
Unit's digit: motor overload 

0: Coast to stop

1: Emergent stop

2: Stop as per stop mode

3: Continue to run

Ten'unit: motor overheat

same as unit'digit

Hundred'unit: too large speed deviation 

same as unit'digit 

Thousand's unit: motor over speed

same as Unit'digit
Unit's digit: PID feedback lost during running

0: Coast to stop

1: Fast stop

2: Stop as per stop mode

3: Continue to run

Ten'unit: Reserved

same as unit'digit

Hundred'unit: reserved 

same as unit'digit

thousand'unit: reserved

same as unit'digit
Unit's digit: output phase loss

0: Coast to stop

1: Fast stop

2: Stop as per stop mode

Ten'unit: EEPROM fault

0: Coast to stop

1: Fast stop

2: Stop as per stop mode

3: Continue to run

Hundred's unit: PG card fault(reserved)

0: Coast to stop

1: Fast stop

2: Stop as per stop mode

3: Continue to run

Thousand's unit: off load fault

0: Coast to stop

1: Fast stop

2: Stop as per stop mode

3: Continue to run
Define as per bit:

bit0-undervoltage;bit1- inverter overload

bit2-inverter overheat ;bit3-motor overload

bit4-motor overheat;bit5-user'fault 1

bit6- user'fault 2; bit7~15 reserved
87
Chapter 5 function code table
0000
0000
0000
0000
0