 PERIODIC SERVICE
(1) Radiator hose
(1) Radiator hose
(1) Radiator hose
Precaution at overheating
Take the following actions in the event the coolant
temperature is close to or more than the boiling point,
which is called "Overheating".
1. Stop the vehicle operation in a safe place, unload
the engine and remain at idle.
2. Don't stop the engine suddenly, but stop it after
about 5 minutes of unloaded idling.
3. Keep yourself well away from the vehicle for at
least 10 minutes or while the steam is blowing out.
4. Check to confirm that there is no danger from the
overheat condition.
76
(2) Clamp band
(2) Clamp band
(2) Clamp band
Details about the cause of the overheat and its
countermeasures can be found in a different
section.
(See TROUBLESHOOTING on page 85.)

3. Checking intake air line

1. Check to see if the hoses and hose clamps are tight
and not damaged.