Omron SYSMAC FH Series User Manual page 348

Vision sensor vision system
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

SerialPlcLinkM
Serial Interface PLC Link (MELSEC QnU/Q/QnAS) communication
IoModule identification name
SerialPlcLinkM
Overview
This is a module is for sending and receiving commands and data via the serial PLC Link interface.
System data
Identification
rsMode
baudRate
byteSize
parity
stopBits
softFlow
timeout
PLC Link data
Identification
commandArea
commandMemoryAddress
responseArea
responseMemoryAddress
outputArea
outputMemoryAddress
handshake
responseTimeout
346
Macro Reference
Meaning
Interface
0: RS-232C
1: RS-422
Baud rate [bps]
Data length [bit]
7 or 8
Parity
0: None
1: Odd number
2: Even number
Stop bits [bit]
0: 1
1: 2
Flow control
0: None
1: Xon/Xoff
Timeout[s]
Meaning
Command area Area
Command area Address
Response area Area
Response area Address
Data Output area Area
Data Output area Address
Handshaking
Retry interval [ms]
WWW.NNC.IR
Initial value
0
9600
7
2
1
0
5
Initial value
CIO Area (CIO)
0
CIO Area (CIO)
100
CIO Area (CIO)
200
1
10000