Omron SYSMAC FH Series User Manual page 831

Vision sensor vision system
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Error message
Fan/voltage error.
Lighting connection has a
problem.
The error concerning
parallel interface was
detected. Turn OFF the
power and check the
connection state of the
parallel interface.
ProcItem error
xxxx: xxxxerror
Failed to paste. Please
check the save source or
the save destination.
A camera outside the
guarantee is connected.
Destination folder is not
found. Please check.
Failed to save the scene
group data. The current
scene group data in the
flash memory is discarded
after restarting.
Recover or avoid by the
following ways.
PLC link error
Failed to register model
Available memory is
insufficient.
It may cause insufficient
memory depending on the
setting.
Vision System FH/FZ5 Series
User's Manual (Z340)
Switch off controller, and verify if fan is affected. If error message is still shown after restart, the
controller may be damaged. Please contact one of our branches or regional offices.
Check the following points.
• Is there a light with a power consumption higher than 7.5 W connected without an external
power supply?
• Is there a light with a power consumption higher than 15 W connected with an external power
supply?
Turn OFF the power and check the connection state of the parallel interface.
This is displayed when the application software detects an abnormality.
Please contact one of our branches or regional offices as there may be a software trouble.
No more scene can be added due to lack of memory.
Review the inspection flow and reduce the memory consumption or switch to another scene
group.
*1:
The display varies depending on the controller.
The remaining capacity of the application is not sufficient for the FH/FZ5-@@ series.
The remaining data memory capacity is not sufficient for the FZ5-L3@@/FZ5-6@@ series.
A camera outside the guarantee is connected to the controller currently being used.
Check the following points.
• Have you deleted the destination folder?
• For cases where he save destination is the folder in the USBDisk, is the USBDisk connected
to the controller? Or, has the USBDisk been detected?
• Save the data to click "Data Save" after increasing free space of the flash memory. Deleting
other scene data, deleting processing units, or setting measurement regions or model
regions as small as possible is effective.
• Change the save destination for the scene group data to the external memory device.
Reference:
Saving Scene Groups in External Memory (p.168)
• Save current scene group data in the external memory device.
Reference:
Saving Settings Data to the Controller RAM Disk or an External Memory
Device (p.258)
PLC link cannot be established. Check the following points.
• Are the FZ communication settings correct?
• Are the PLC communication settings correct?
• Is cable connected correctly?
Search, classification, flexible search, shape search+, shape search II
Please register higher-contrast images as models. If the model is registered at full screen size,
re-register at a smaller size.
For fine matching
For the fine matching, the two pixels at the edge of the image cannot be registered as the
model.
Available application memory is low.
Memory may become insufficient during operation or an error may occur when the operation
mode is switched.
Review the inspection flow and reduce the memory consumption.
WWW.NNC.IR
Troubleshooting
*1
Error Messages and Troubleshooting
8
829