IMPORTANT
• Click the upper left of the Image Display Pane and set the [Image mode] to [Freeze Image].
Reference:
Changing the Image Mode and Other Display Contents (p.92)
• If images are taken consecutively at high speed, the number of images that you will be able to take will be limited. If the
maximum number of images have been taken, the READY signal will not turn ON until the current processing is completed.
Therefore, the next STEP signal cannot be input.
• The ERROR terminal turns ON if a STEP signal is input when the READY signal is OFF.
• If the trigger signal input rate is faster than the communications output, some STEP signals may be skipped and
measurements may be delayed. Make sure to input trigger signals at a rate that does not cause a delay in
communications.
• The multi-input function cannot be used in the following cases:
• The flow has more than one camera input processing unit.
• The flow has a Camera Image Input HDR processing unit.
• Branching is used to process a single camera input processing unit more than one time.
• Measurement triggers are input through means other than parallel or EtherCAT communications (non-procedure
commands or measurement commands through a PLC Link).
• If a measurement trigger is input while using the multi-input function, the last NG image cannot be displayed.
• If images and data are logged to a network drive, the use of the multi-input function and other heavy measurement loads
on the Controller may slow down communications and cause logging errors. In this case, set the measurement takt time
so that there is some leeway.
• When the multi-input function is in use, most of the resources of the CPU are allocated to measurement processing. This
may cause performance drops (delayed responses and packet losses) and communications errors. Do not use Ethernet/
IP communications while the multi-input function is in use.