Example
Uses the *MEASUREDISPG subroutine of the Unit Macro processing unit to simultaneously display
registered model figures for the search processing units (Processing Unit numbers 5, 6, 7, and 8). The model
registration figure of the Search processing item is figure 0. (Reference:
Use the Dim function to define an array with element number that is larger than the element number used for
the figure data.
*MEASUREDISPG
Dim FIGURE1&(255), FIGURE2&(255), FIGURE3&(255), FIGURE4&(255)
Rem Get the figure data of the model figure.
GetUnitFigure 5, 0, FIGURE1&()
GetUnitFigure 6, 0, FIGURE2&()
GetUnitFigure 7, 0, FIGURE3&()
GetUnitFigure 8, 0, FIGURE4&()
Rem Draw the image
DrawFigure FIGURE1&(), 0, UnitNo
DrawFigure FIGURE2&(), 0, UnitNo
DrawFigure FIGURE3&(), 0, UnitNo
DrawFigure FIGURE4&(), 0, UnitNo
Return