Convert Axis Movement processing item · · · Set the machine setting processing item to reference. Then set the
Data output processing item
Example 2: Alignment Flow Example (Movement Multi Points) for Two Cameras
Camera Image Input item
Reference Calib Data processing item
Position measurement processing item
Camera Switching processing item
Reference Calib Data processing item
Position measurement processing item
Movement Multi Points processing item · · · Set the machine setting processing item to reference. Then set the
Data output processing item
Vision System FH/FZ5 Series
User's Manual (Z340)
expressions for the two Position Data Calculation processing items,
[Calculate position XY] and [Calculate angle TH], in the [Reference position
XY] and [Reference angle], and the [Measurement position XY] and
[Measurement angle] in the Movement Single Position processing item.
Before you execute the measurement, set the [Current setting] with the
position of the axis of the external device when the measurement was
performed.
· · · Depending on the communications method, register either [Data output]
or [Fieldbus data output].
Send each [Axis movement] expression in the Movement Single Position
processing item to the PLC.
· · · Select Camera 0.
· · · Select the Vision Master Calibration or PLC Master Calibration
processing item on the calibration scene with the reference calibration
data.
· · · Measure the position of the alignment marks or the position of a special
feature of the workpiece from the image in Camera 0.
To output the actual coordinates of the position, set [Calibration] on the
[Output parameter] tab page to OFF.
Set the workpiece in reference position and then set the reference
position.
· · · Select Camera 1.
· · · Select the Vision Master Calibration or PLC Master Calibration
processing item on the calibration scene with the reference calibration
data.
· · · Measure the position of the alignment marks or the position of a special
feature of the workpiece from the image in Camera 1.
To output the actual coordinates of the position, set [Calibration] on the
[Output parameter] tab page to OFF.
Set the workpiece in reference position and then set the reference
position.
expressions for the position measurement processing items, [Reference
XY] and [Measure XY] in the [Reference position XY] and [Measurement
position XY] in the Movement Multi Points processing item.
Before you execute the measurement, set the [Current setting] with the
position of the axis of the external device when the measurement was
performed.
· · · Depending on the communications method, register either [Serial data
output] or [Fieldbus data output].
Send each [Axis movement] expression in the Movement Multi Points
processing item to the PLC.