Omron SYSMAC FH Series User Manual page 699

Vision sensor vision system
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Example
In normal UDP communication, specifies the destination and sends data.
Rem Create the destination address information (10.1.1.101)
Dim IPADDR&(4)
IPADDR&(0) = 10
IPADDR&(1) = 1
IPADDR&(2) = 1
IPADDR&(3) = 101
Rem Make the transmit data.
Dim BUFFER&(4)
BUFFER&(0) = 1
BUFFER&(1) = 2
BUFFER&(2) = 3
BUFFER&(3) = 4
BUFFER&(4) = 5
Rem Transmit the data selected address.
SendData "UdpNormal", BUFFER&(), 4 * 5, IPADDR&(), 4 * 4
In PLC link, specifying the offset value and writing data to the data output area.
Rem Create the offset data.
Dim OFFSET&(0)
OFFSET&(0) = 2
Rem Make the transmit data.
Dim BUFFER&(4)
BUFFER&(0) = 1
BUFFER&(1) = 2
BUFFER&(2) = 3
BUFFER&(3) = 4
BUFFER&(4) = 5
Rem Use the offset value to send the data.
SendData "SerialPlcLink", BUFFER&(), 4 * 5, OFFSET&(), 4 * 1
Useable Modules
Scene Control Macro / Communication Command Macro / Unit Macro
Supported Versions
Version 3.50 or later
Related Items
ReceiveData (Reference:
Vision System FH/FZ5 Series
User's Manual (Z340)
Details (p.651))
WWW.NNC.IR
SendString (Reference:
Details (p.698))
Macro Reference