Error Messages and Troubleshooting

This section lists error messages that display on the screen and solutions.
When a message with this symbol is displayed, the ERROR signal on the parallel interface is on.
Error message
No value set. Be sure to set
up value.
• Invalid system disk
Replace the disk, and
then press any key.
• Remove disks or other
media. Press any key to
restart.
Error of the expression.
Cannot add object. Out of
range of specified
characters of expression.
The problem occurred in
the camera connection.
Failed to start the window.
Memory is insufficient.
Warning range shall be set
within the range from
judgement lower to upper
limit.
The "Search"
measurement result may
be "NG (Insufficient
memory)" with the current
setting.
It failed in preservation
because the free space of
the flash memory was
insufficient.
Vision System FH/FZ5 Series
User's Manual (Z340)
A value must be set for this item. Please set up value.
An error occurred in USB memory. End the Controller and turn OFF the power supply. Then
back up the data from the USB memory device that you removed from the Controller and then
physically format it on your computer with a physical formatting tool. If the problem cannot be
solved by physically reformatting the USB memory device, it may be damaged.
Do the following errors exist in settings for an expression set up?
• Different number of open/close parentheses
• TJG/unit/value/function/operator/comma is lined next to each other.
• Operator is set at beginning or end of expression
• The number of function operands is insufficient or there are more than is needed
Incompliant to the conditions of expression. Please check the content.
Reference:
Calculation-Settings (Calculation) in the Vision System FH/FZ5 Series
Processing Item Function Reference Manual (Cat No. Z341).
Is the camera cable connected to the controller?
Is camera cable disconnected?
Do [Select camera] of [Camera Image Input] and [Camera Switching] have any errors?
Please check the contents of [Camera setting], then switch off and restart.
Reference:
Camera Image Input-Camera Settings in the Vision System FH/FZ5 Series
Processing Item Function Reference Manual (Cat No. Z341).
Because memory available for use was insufficient, memory needed to open the window could
not be secured. Check the flow by adjusting the measurement region of each processing unit
and the sizes of the registered models.
• [Shape search]
If shape search+ setup window is opened while the RAMDisk memory is insufficient for
image logging, etc. on the RAMDisk, a warning message is displayed. In the case that an
image logging file is stored in a RAMDisk, please move the content on the RAMDisk to a
USBDisk to open up memory and reopen the set up window.
Please redefine the upper and lower warning range limits such that they are within the range
between the lower and upper evaluation limits.
Reference:
Trend Monitor-Judgement Conditions (Trend Monitor) in the Vision System FH/
FZ5 Series Processing Item Function Reference Manual (Cat No. Z341).
Insufficient memory may occur during measurement. Reset the model parameters.
• [Search]
Reference:
Search - Judgement is NG (Insufficient Memory) in the Vision System FH/FZ5
Series Processing Item Function Reference Manual (Cat No. Z341).
• [Flexible search]
Reference:
Flexible search - Judgement is NG (Insufficient Memory) in the Vision System
FH/FZ5 Series Processing Item Function Reference Manual (Cat No. Z341).
• [Classification]
Reference:
Classification - Judgement is NG (Insufficient Memory) in the Vision System
FH/FZ5 Series Processing Item Function Reference Manual (Cat No. Z341).
The scene group data size may be too big.
Use external memory and save the data to a scene group other than group 0 or change the
measurement flow.