Saving Scene Groups In External Memory - Omron SYSMAC FH Series User Manual

Vision sensor vision system
Hide thumbs Also See for SYSMAC FH Series:
Table of Contents

Advertisement

Saving Scene Groups in External Memory

The scene group storage location specification function lets you specify a location other than the Sensor
Controller's flash memory for saving scene group data. After specifying the desired storage location with this
function, menus and buttons such as "Data save"save set data in the specified external memory instead of in the
Sensor Controller's flash memory. This function is handy as it enables use of external memory when the volume
of scene group data is too large to save all of it in the Sensor Controller's flash memory.
1
Select [Scene Group Saving Destination Setting] from the [Tool] menu in the main screen.
A screen for specifying the scene group storage location appears.
2
Set each item in the [Scene group saving destination on settings] area.
Variable name
Scene Group
Saving Destination
Setting
Scene group No.
168

Saving Scene Groups in External Memory

Set value [Factory default]
• [Save all scene group data in
the flash memory]
• Save all scene group data in the
external memory device
• Save after the next scene group
data in the external memory
device
0 to 9999[1]
WWW.NNC.IR
Content
Sets the storage location for scene group data.
• Store all in Sensor Controller memory
• Store all in external storage device
• Store scene groups after scene group below in external
storage device
This setting is valid when [Save after the next scene group
data in the external memory device] is selected for [Scene
Group Saving Destination Setting].
Used to set the number of the first scene group to store in
external memory.
For the FH/FZ5 series, if 32 or above is specified for the
scene group number, all scene group data will be saved to
the Sensor memory.
Vision System FH/FZ5 Series