Scope of Data and Save Area

Necessity of referring
to this manual
In macro customize functions, many types of data can be used as needed for the objective, and variables and
macro functions can be used to set and acquire data.
The areas where data settings and acquisition can be executed and the areas where data are saved vary
depending on the type of data.
By using data types appropriately for the objective of the program, macro customize functions enable the
creation of programs that are easy to change and maintain.
Data Scope
The locations from which data can be set and acquired are limited; data cannot be set or acquired from any
location. This limited location is called a "scope", and data can only be set and acquired from within the scope
defined for that data type.
Data scopes that can be used with the macro customize functions are as follows.
Scope
Within a processing unit
Within a communication command
macro
Within a scene
Within the system
Vision System FH/FZ5 Series
User's Manual (Z340)
Communication
Unit Macro
Command Macro
Only enabled within one processing unit.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow,
variables with the same name that exist in the processing units will be treated
as separate variables.
If multiple communication command macros are defined in the
communication command macro tool, variables with the same name that exist
in the communication command macros will be treated as separate variables.
Enabled within one scene.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow, the
same data can be set and acquired from each processing unit.
The data cannot be set or acquired from the processing unit of a different
scene.
Enabled with the system.
If multiple processing units of the "Unit Macro" processing item or the "Unit
Calculation Macro" processing item are included in the measurement flow, the
same data can be set and acquired from each processing unit.
If multiple communication command macros are defined in the
communication command macro tool, the same data can be set and acquired
from each communication command macro.
The data can be set and acquired from all scene groups and scenes.