Section 3: Service Setup
Inspection item
Color saturations.
Criteria
• The SMPTE BAR is not missing.
• Color levels should be sufficient and normal.
• There are not any abnormal lines on the image
3.10 Optical Performance Measure
Conditions
• Ambient luminance: <10.0 Lux.
• Lens: 0.8:1
• Product must be warmed up for 5 minutes.
• Distance from the screen: 2 meters.
• Screen Size: 60 inches diagonal (16:9 format).
3.10.1 Test Equipment
Procedure
1. Press M
ENU
Keypad to enter Factory Mode.
2. Select Spoke.
3.10.2 Brightness
Procedure
1. Display the Full White pattern.
2. Use a light meter to measure the brightness values of P1 to P9.
3. Follow the brightness formula to calculate brightness values.
4. Brightness Formula: Avg(P1~P9)*1.04m².
3-10
, A
, L
, L
, L
UTO
EFT
EFT
EFT
keys sequentially on Remote or Built-in
E Series 675/775 Service Manual
020-000546-04 Rev. 1 (04-2017)