Section 3: Service Setup
3. Use the uniformity formula to calculate the average values.
• Uniformity Formula:
ANSI Uniformity = [Max(P1,P2,...,P12,P13)/Avg.(P1,P2,...,P8,P9)-1]×100% or
ANSI Uniformity = [Min(P1,P2,...,P12,P13)/Avg.(P1,P2,...,P8,P9)-1]×100%

Criteria

• Full white ANSI 13-pt all lamp models in all modes of operation:
• Nominal: <+7%, >-14%
• Maximum: <+20%, >-20%
• Full black ANSI 13-pt all lamp models in all modes of operation:
• Maximum: <+65%,>-50%

3.11 PIP Function Test

1. Navigate to: Main Menu > Input Switching & PIP.
2. Set PIP/PBP Enable to On.
3. Check that each item in the Input Switching & PIP menu is
functioning.
Table 3.6 Split Screen Compatibility Matrix
Main
HDMI
1
PIP/PBP
HDMI1
HDMI2
v
Display Port
VGA
BNC
v
Component
S-Video
v
CVBS
v
RJ45
v
USB type B
v
(mini)
USB type A
v
NOTE: There must be two input signals. "v" means the projector can display the two sources simultaneously.
3-12
HDMI
Display
VGA
2
Port
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
BNC
Component
S-Video
v
v
v
v
v
v
v
v
v
v
v
CVBS
RJ45
v
v
v
v
v
v
v
v
v
v
v
v
E Series 675/775 Service Manual
020-000546-04 Rev. 1 (04-2017)
USB
USB
Type B
Type A
(mini)
v
v
v
v
v
v
v
v

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dwu675-eDhd675-eDwu775-eDhd775-e

Table of Contents