Procedure; Power Inlet; Ir Sensor; Photo Sensor Board - Christie E Series Service Manual

Hide thumbs Also See for E Series:
Table of Contents

Advertisement

6. Disconnect from ground stud located under Power Supply board.
7. Remove screws (2). See Figure 5-44.
8. Replace Power Inlet.

5.2.27IR Sensor

Replacement Time: 45 minutes

Procedure:

1. Remove Top Cover. See
2. Remove Top Shield. See
3. Disconnect from Main Board. See
4. Remove from pressure clip. See Figure 5-45.
5. Replace IR Sensor.

5.2.28Photo Sensor Board

Replacement Time: 25 minutes
Procedure:
1. Remove Top Cover. See
2. Remove Top Shield. See
3. Remove Lens Assembly. See
4. Disconnect harnesses (2).
5. Remove screws (2). See Figure 5-46.
6. Replace Photo Sensor Board.
5.2.29Shutter
Replacement Time: 25 minutes
Procedure:
E Series 675/775 Service Manual
020-000546-04 Rev. 1 (04-2017)
F
5-44 R
IGURE
EMOVE
5.2.5 Top
Cover.
5.2.7 Top Shield.
5.2.38 Main
Board.
5.2.5 Top
Cover.
5.2.7 Top Shield.
5.2.3 Lens
Assembly.
Section 5: Parts and Module Replacement
P
I
OWER
NLET
F
F
5 46 P
IGURE
5-45 IR S
IGURE
ENSOR
S
B
HOTO
ENSOR
OARD
5-27