3.1.2 Prism Offset

If the lamp mode is set to Lamp 1, the prism value should be 0. If Lamp 2, the value should be 632. If Dual
lamp, the value should be 316. If this value is not changing, the prism mechanism may not be moving
correctly, resulting in the unit being dimmer than expected.

3.1.3 Service Mode

Using the Remote or Built-in Keypad, perform the following actions to get into Service Mode:
1. Turn on the projector.
2. Navigate to: Main Menu > Configuration > Service
3. Press 4, 7, 5, 3 sequentially (Service Code).
4. Select OK and then press E
3.2

OSD Reset

The following actions will allow you to erase all end-users' settings and restore the default OSD setting:
1. Enter Service Mode, as in
2. Select Factory Reset.
3.3

Reset Lamp Hours

After replacing the Lamp Module, reset lamp hours using the Remote or Built-in Keypad as follows:
1. Navigate to: Main Menu > Lamp > Reset Lamp Hours
2. Select 1, 2 or Both to reset the lamp hours.
3. Press E
NTER