Section 3: Service Setup
Table 3.1 Factory Mode
FACTORY MODE
ABC Calibration
Lens Type
Spoke
Sequence Code
WaveForm
Fan
Exit
Lens Calibration
Lens Top Pos.
Lens Moving
Prism Calibration
Prism Center Pos.
Prism Left Pos.
Prism Right Pos.
Prism Offset
BCLook
Test Pattern
Custom Pattern
Ballast Eco Mode
Error Log
DQE Test
DQE Reset
LampVoltage
FanRpm
LampGain
Sequence Code
upgrade
Freezer
Gamma table
Factory Status
LED
Mode Adjust
Driver Temper
3-2
Perform calibration of Auto Brightness Sensor
Press L
and R
EFT
IGHT
keys to select Lens Type
Generate pattern from DDP3021, (press S
to exit)
Press L
and R
EFT
IGHT
keys to set Sequence Code
Press L
and R
EFT
IGHT
keys to set WaveForm
Press S
ELECT
key to do Fan Calibration
Press H
ELP
key to do Lens Calibration
Press H
ELP
key to do Lens Calibration and move to top
Press H
ELP
key to do Lens Calibration and move to top, bottom, left and right
position
Press H
ELP
key to do Prism Calibration
Press H
ELP
key to shift Prism to center position
Press H
ELP
key to shift Prism to left position
Press H
ELP
key to shift Prism to right position
Press L
and R
EFT
IGHT
keys to set motor step from sensor
BrilliantColor™ mode selection
Generate pattern from DDP3021 (press S
to exit)
Generate pattern from DDP3021
0: Lamp Power 280W, 1: Lamp Power 330W
Show Fanlock, over Temp, Lamp1 Lite Fail, Lamp2 Lite Fail, Lamp1 Ignition
Fail, Lamp2 Ignition Fail, Prism Sensor1 Fail, Prism Sensor2 Fail Error Log
For DQE test
For DQE test
Press S
ELECT
key to get Lamp Voltage and thermal external temperature
Show current Fan Rpm
Show Lamp Mode
Upgrade SQ code via VGA
Unused
Gamma Correction - 0:TI Film, 1:TI Graphics Enhanced , 2:TI Video Enhanced
(NTSC, PAL, SECAM), 3:Linear, 4~8:OEM defined tables
(Prism right sensor state. Prism left sensor state) - (Shutter Sensor State) -
(Thermal external temperature)
Test LED
Adjust source H,V position
Displays internal temperature
DESCRIPTION
key to change pattern, M
ELECT
key to switch pattern , M
ELECT
ENU
key
ENU
key
E Series 675/775 Service Manual
020-000546-04 Rev. 1 (04-2017)