ODU MOUNTING
10 Connect the wave guide to the transducer for the ODU.
Waveguide
Bolt (M4)
Spring washer
Notes
Waveguide
Bolt(M4)
Spring washer
Refer to 5.2.2 ODU Mounting for Waveguide Connection
Installation
Submission Prohibited
NEC Internal Use Only
O-ring
Washer
1.
Tightening torque is 1.4 N·m ±10% (up to 15 GHz).
Tightening torque is 0.6 N·m ±10% (18 GHz or higher).
2.
Be careful not to damage the O-ring.
O-ring
Washer
For 10/11 GHz
A
ODU 10/11 GHz)
A
ODU 13-38 GHz)
Details of A
For 13-38 GHz
5-63