CABLE TERMINATION
Tools
6
Connector assembly
(1) The cable center conductor must be straight and aligned with the connector
(2) The gap of the connector body and clamp nut is confirmed.
Notes
Tools
Installation
Submission Prohibited
NEC Internal Use Only
•
cutter
•
measure
•
file, etc.
inner contact. Insert the cable into the connector body until stopped; the center
conductor must be inserted into the connector inner contact fingers. Tighten
the connection to the torque value of 60 to 80 lb-in (6.8 to 9.0 N·m).
Gap: 0 to 0.5 mm
1.
When inserting, do not put the chip which is braided wire inside the
central conductor and the connector body
2.
Do not turn connector body, turn clamp nut attachment.
•
spanner (16 mm)
•
torque spanner (15 mm)
60-80 lb-in
)
(6.8-9.0 N·m
0 to 0.5 mm
6-27