0010H
1 = Hardware underflow
2 = Hardware overflow
3 = Software underflow
4 = Software overflow
-
The limits of the internal processor hardware stack or of software stack in the data mem-
ory have been violated. The cause is probably a hardware error on the control module.
Reload drive software. Replace the control module.
0011H
Opcode address
-
The watchdog on the control module has timed out. The cause is a hardware error in the
time base on the control module.
Replace the control module.
0012H
-
-
The NC basic cycle which is generated on the NC and transferred to the drive via the
drive bus cable has failed.
Possible causes: NCK reset, EMC interference, NC hardware error, cable break on the
drive bus, hardware error on the control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the NC hardware, replace the control module.
0013H
-
-
The NC basic cycle which is generated on the NC and transferred to the drive via the
drive bus cable has supplied a pulse which does not match the clock timing.
Possible causes: EMC interference on drive bus, NC hardware error, hardware error on
the control module.
Check the drive bus cable and cable connections, perform remedial measures (check
shielding or ground connection). Replace the NC hardware, replace the control module.
0014H
Incorrect address
-
The processor has detected an illegal command in the program memory.
Replace the control module.
1 Alarms
1-591