1 Alarms
Reactions:
Remedy:
Program Continuation:
15910
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15950
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15960
Parameters:
Definitions:
Reactions:
1-218
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Include a probe number within the limits given above in the keyword MEAS=... This must
correspond to the hardware connection of the probe.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 touch probe not allowed
%1 = Channel number
%2 = Block number, label
Measure without deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAW
(measure without distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAW=2 G01 X100 Y200 Z300 F1000
Probe 2 without deletion of distance-to-go
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Include a probe number within the limits given above in the keyword MEAW=... This must
correspond to the hardware connection of the probe.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no traverse motion programmed
%1 = Channel number
%2 = Block number, label
Measure with deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the
command MEAS (measure with deletion of distance-to-go).
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Correct the part program and add the axis address or the traversing path to the measure-
ments block.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no traverse motion programmed
%1 = Channel number
%2 = Block number, label
Measure without deletion of distance-to-go
In the part program, no axis or a traversing path of zero has been programmed with the
command MEAW (measure without deletion of distance-to-go).
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02