1 Alarms
Reactions:
Remedy:
Program Continuation:
12520
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12530
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-144
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Divide up the part program block into several blocks.
• If necessary, use the local variable for storing intermediate results.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 too many tool parameters %3
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
In the part program, in the tool offset file (..._TOA) and in the initialization file (..._INI), no
more than 5 tool offset parameters may be used per block.
Example:
N ...
N 100 $TC_DP1 [5,1] = 130, $TC_DP3 [5,1] = 150.123,
$TC_DP4 [5,1] = 223.4, $TC_DP5 [5,1] = 200.12,
$TC_DP6 [5,1] = 55.02
N ...
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
• Divide up the part program block into several blocks.
• If necessary, use the local variable for storing intermediate results.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid index for %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
In macro definitions, an attempt was made to define a G function with more than 3
decades or an M function with more than 2 decades as identifier of the macro.
Example:
_N_UMAC_DEF DEFINE G4444 AS G01 G91 G1234
DEFINE M333 AS M03 M50 M99
:
M17
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block.
Modify the macro definition in accordance with the Programming Guide.
Clear alarm with NC START or RESET key and continue the program.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02