Definitions:
Reactions:
Remedy:
Program Continuation:
14117
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14118
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14119
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
14120
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
The orientation has been entered as an absolute value (e.g. by a direction vector)
although ORIPATH is active. When ORIPATH is active, the orientation is determined from
the leading and sidewards angles relative to the path tangent and surface normal.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no angle or direction of the cone programmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation (ORICONCW and ORICONCC),
either the opening angle or the direction vector of the taper must be programmed. Other-
wise, the change of orientation is not clearly defined.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no end orientation programmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation, no end orientation has been pro-
grammed. The change of orientation is therefore not clearly defined.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 no intermediate orientation programmed
%1 = Channel number
%2 = Block number, label
With taper circumference interpolation of orientation with ORICONIO, an intermediate ori-
entation must also be programmed in addition to the end orientation.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 plane determination for programmed orientation not possible
%1 = Channel number
%2 = Block number, label
The programmed orientation vectors (direction vectors) in the beginning of block and end
of block point include an angle of 180 degrees. Therefore the interpolation plane cannot