Siemens SINUMERIK 840D Series Diagnostics Manual page 212

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

1 Alarms
Reactions:
Remedy:
Program Continuation:
15185
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15190
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15300
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
15310
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
1-212
- Alarm display.
Correct the initialization program (INI file), or the GUD or macro definition file (DEF file).
In connection with Alarm 12380 or 12460, also change the memory configuration.
Clear alarm with the Delete key or NC START.
Channel %1 %2 errors in INI file
%1 = Channel number
%2 = Number of detected errors
Errors were found when processing initialization programs (INI files), GUD or macro defi-
nition files (DEF files).
- Alarm display.
- Interface signals are set.
- NC Start disable in this channel.
Please inform the authorized personnel/service department. Correct the INI or DEF file or
correct the MD and create a new INI file (via "Upload").
Switch control OFF - ON.
Channel %1 block %2 not enough free memory for subroutine call
%1 = Channel number
%2 = Block number, label
The following deadlock has been found in the interpreter: Memory is needed for calling a
subroutine. The module memory is, however, empty and there is no prospect of module
memory becoming free again by executing the preprocessing/main run queue, because
this queue is empty.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Please inform the authorized personnel/service department. Increase machine data
28010 MM_NUM_REORG_LUD_MODULES/28040 MM_LUD_VALUES_MEM / 18210
MM_USER_MEM_DYNAMIC or program a preprocessing stop STOPRE before calling
the subroutine.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid number-of-passed-blocks during block search
%1 = Channel number
%2 = Block number, label
In the function "Block search with calculation" a negative number of passes has been
entered in column P (number of passes). The permissible range of values is P 1 - P 9 999.
- Alarm display.
Enter only positive number of passes within the range of values.
Clear alarm with the Delete key or NC START.
Channel %1 block %2 file requested during block search is not available
%1 = Channel number
%2 = Block number, label
During block search, a target has been specified with a program that has not been loaded.
- Alarm display.
Correct the specified search target accordingly or reload the file.
Clear alarm with the Delete key or NC START.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents