Siemens SINUMERIK 840D Series Diagnostics Manual page 513

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
300759
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
300760
Parameters:
Definitions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- NC not ready.
- Channel not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
Modify drive machine data
• Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) or
• Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator
control) or
• Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator con-
trol) or
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 generator mode: response voltage > monitoring threshold
%1 = NC axis number
%2 = Drive number
The value in MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) is greater than MD1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response
threshold for DC link monitoring).
- NC not ready.
- Channel not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
Modify drive machine data
• Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) or
• Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for
DC link monitoring).
Clear alarm with the RESET key in all channels. Restart part program.
Axis %1 drive %2 generator mode: emergency retraction speed > max. motor
speed
%1 = NC axis number
%2 = Drive number
The value entered for the emergency retraction speed in MD1639:
$MD_RETRACT_SPEED (emergency retraction speed) is greater than MD1146:
$MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
1 Alarms