1 Alarms
Remedy:
Program Continuation:
61243
Definitions:
Reactions:
Remedy:
Program Continuation:
61244
Definitions:
Reactions:
Remedy:
Program Continuation:
61246
Definitions:
Reactions:
Remedy:
Program Continuation:
61247
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61248
Definitions:
Reactions:
1-396
Check programmed parameters.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Correct tool change point, tool tip is in retraction area!
The tool change point has to be far enough outside the retraction area so that when the
revolver is swivelled, no tool extends into the retraction area.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Specify another tool change point.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Thread lead change results in an undefined thread
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Check thread geometry.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Safety clearance too small
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase safety clearance.
Internal
Channel %1 block %2: Blank radius too small
%1 = Channel number
%2 = Block number, label
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Increase blank radius.
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Infeed too small
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved