1 Alarms
Reactions:
Remedy:
Program Continuation:
12340
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12350
Parameters:
Definitions:
Reactions:
1-136
• from STRING to: REAL: -, INT: -, BOOL: yes2), CHAR: only if 1 character, STRING:
yes, AXIS: -, FRAME: -
• from AXIS to: REAL: -, INT: -, BOOL: -, CHAR: -, STRING: -, AXIS: yes, FRAME: -
• from FRAME to: REAL: -, INT: -, BOOL: -, CHAR: -, STRING: -, AXIS: -, FRAME: yes
1) Value <> 0 corresponds to TRUE, value ==0 corresponds to FALSE.
2) String length 0 => FALSE, otherwise TRUE.
*) At type conversion from REAL to INT fractional values that are >=0.5 are rounded up,
others are rounded down.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Check transfer
parameters of the subroutine call and define the application accordingly as call-by-value
or call-by-reference parameter.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 number of parameters too high %3
%1 = Channel number
%2 = Block number, label
%3 = Source string
When calling a function or a procedure (predefined or user-defined) more parameters
were transferred than defined.
Predefined functions and procedures: The number of parameters has been set perma-
nently in the NCK.
User-defined functions and procedures: The number of parameters is established by type
and name in the definition.
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. Check whether
the correct procedure/function has been called. Program the number of parameters in
accordance with the procedure/function.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 parameter %3 no longer possible
%1 = Channel number
%2 = Block number, label
%3 = Source string
An attempt has been made to transfer actual parameters although axis parameters
located before them have not been assigned. For procedure or function calls, assignment
of parameters that are no longer required can be omitted, if subsequently no further
parameters are to be transferred. Example: N10 FGROUP(X, Y, Z, A, B) ; max. 8 axes
possible The following call-by-value parameters would then be initialized with zero
because the space-dependent assignment has been lost on account of the omitted axis
parameters.
Axes that can be omitted and following parameters do not occur in the predefined proce-
dures and functions.
- Alarm display.
- Interface signals are set.
- Correction block
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents