1 Alarms
Reactions:
Remedy:
Program Continuation:
380075
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
380500
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
400102
Definitions:
Reactions:
Remedy:
Program Continuation:
400103
Definitions:
Reactions:
Remedy:
Program Continuation:
400106
Definitions:
Reactions:
Remedy:
Program Continuation:
1-570
- Alarm display.
- Interface signals are set.
- Channel not ready.
- NC Start disable in this channel.
Only use addresses >= 128 for output slots.
Enter correct base addresses in the machine data:
• For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
• For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
• NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text
and contact the control system manufacturer.
Switch control OFF - ON.
Profibus DP: DP I/O failure slave %1
%1 = Slave address
Failure of a PROFIBUS slot used by the NCK for digital or analog I/O.
- Alarm display.
Check that the PROFIBUS slave is operating correctly (all slaves must be included in the
bus, green LED).
Alarm display showing cause of alarm disappears. No further operator action
Profibus-DP: fault on drive %1, code %2, value %3, time %4
%1 = Axis
%2 = Fault code of drive (P824)
%3 = Fault value of drive (P826)
%4 = Fault time of drive (P825)
Contents of fault memory of assigned drive.
- Alarm display.
See drive documentation for fault codes/fault values.
Alarm display showing cause of alarm disappears. No further operator action
Delete DB 2 in the PLC and restart
-
- -
See the machine manufacturer's information.
Internal
Delete DB 3 in the PLC and restart
-
- -
See the machine manufacturer's information.
Internal
Delete DB 3 in the PLC and restart
-
- -
See the machine manufacturer's information.
Internal
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02