1 Alarms
Remedy:
Program Continuation:
12475
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12480
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
12490
Parameters:
Definitions:
1-142
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. You should
decide on the basis of the machine manufacturer's programming guide whether or not the
displayed G function exists or is available, or whether a standard G function has been
reconfigured (or introduced by an OEM). Remove G function from the part program or
program function call in accordance with the machine manufacturer's programming guide.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 invalid G function number %3 programmed
%1 = Channel number
%2 = Block number, label
%3 = G code number
A non-allowed G function number (parameter 3) has been programmed for a G group with
indirect G code programming. Only the G function numbers indicated in the Programming
Guide "Fundamentals", Section 12.3 "List of G functions/Path conditions" are allowed.
- Alarm display.
- Interface signals are set.
- Correction block is reorganized.
Modify part program.
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 subroutine %3 already defined
%1 = Channel number
%2 = Block number, label
%3 = Source string
The name used in the PROC or EXTERN instruction has already been defined in another
call description (e.g. for cycles).
Example:
EXTERN CYCLE85 (VAR TYP1, VAR TYP2, ...)
- Alarm display.
- Interface signals are set.
- Correction block
Press the NC Stop key and select the function "Correction block" with the soft key PRO-
GRAM CORRECT. The correction pointer positions on the incorrect block. A program
name must be selected that has not yet been used as identifier. (Theoretically, the param-
eter declaration of the EXTERN instruction could also be adapted to the existing subrou-
tine in order to avoid the alarm output. However, it would have been defined identically
twice).
Clear alarm with NC START or RESET key and continue the program.
Channel %1 block %2 access permission level %3 is not valid
%1 = Channel number
%2 = Block number, label
%3 = Source string
The desired access authorization, programmed with the keyword REDEF, has not been
set. The desired protection level is either beyond the permitted value range or the protec-
tion level change is not allowed.
(The REDEF instruction is only executable in INITIAL_INI blocks on SINUMERIK 840D,
P1 (6/94)).
The protection level may be changed only if:
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
 Siemens AG, 2002. All rights reserved
11.02