1 Alarms
61234
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61235
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61236
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
61237
Parameters:
Definitions:
Reactions:
1-394
Channel %1 block %2 ShopMill subroutine %4 cannot be executed, as it has not
been tested by ShopMill
%1 = Channel number
%2 = Block number, label
Before a ShopMill subroutine can be used, it has to be tested by ShopMill. Alarm triggered
by following cycles: E_HEAD.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
The subroutine has to be simulated first in ShopMill or loaded into the ShopMill operating
mode "Machine auto".
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: ShopTurn program %4 cannot be executed, as it has not
been tested by ShopTurn.
%1 = Channel number
%2 = Block number, label
%3 = Program name
Before a ShopTurn program can be executed, it has to be tested by ShopTurn.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode
"Machine auto".
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: ShopTurn subroutine %4 cannot be executed, as it has not
been tested by ShopTurn.
%1 = Channel number
%2 = Block number, label
%3 = Subroutine name
Before a ShopTurn program can be executed, it has to be tested by ShopTurn.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode
"Machine auto".
Clear alarm with the RESET key. Restart part program
Channel %1 block %2: Retraction direction unknown. Manually retract tool!
%1 = Channel number
%2 = Block number, label
-
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02