The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- NC not ready.
- Channel not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- The NC switches to follow-up mode.
- Alarm display.
- Interface signals are set.
Please inform the authorized personnel/service department.
The bandwidth denominator of a current or speed setpoint filter must be less than twice
the natural frequency.
• Speed setpoint filter 1:
• MD 1515 <= 2 * MD 1514 * 0.01 * MD 1520
• Speed setpoint filter 2:
• MD 1518 <= 2 * MD 1517 * 0.01 * MD 1521
• Current setpoint filter 1:
• MD 1211 <= 2 * MD 1210
• Current setpoint filter 2:
• MD 1214 <= 2 * MD 1213
• Current setpoint filter 3:
• MD 1217 <= 2 * MD 1216
• Current setpoint filter 4:
• MD 1220 <= 2 * MD 1219
• Modify MD 1515: $MD_SPEED_FILTER_1_BANDWIDTH (bandwidth speed setpoint
filter 1)
• Modify MD 1514: $MD_SPEED_FILTER_1_SUPPR_FREQ (suppression frequency
speed setpoint filter 1)
• Modify MD 1520: $MD_SPEED_FILTER_1_BS_FREQ (bandstop filter natural fre-
quency speed setpoint filter 1)
• Modify MD 1518: $MD_SPEED_FILTER_2_BANDWIDTH (bandwidth speed setpoint
filter 2)
• Modify MD 1517: $MD_SPEED_FILTER_2_SUPPR_FREQ (suppression frequency
speed setpoint filter 2)
• Modify MD 1521: $MD_SPEED_FILTER_2_BS_FREQ (bandstop filter natural fre-
quency speed setpoint filter 2)
• Modify MD 1211: $MD_CURRENT_FILTER_1_BANDWIDTH (bandwidth current set-
point filter 1)
• Modify MD 1210: $MD_CURRENT_FILTER_1_SUPPR_FREQ (suppression fre-
quency current setpoint filter 1)
• Modify MD 1214: $MD_CURRENT_FILTER_2_BANDWIDTH (bandwidth speed set-
point filter 2)
• Modify MD 1213: $MD_CURRENT_FILTER_2_SUPPR_FREQ (suppression fre-
quency current setpoint filter 2)
• Modify MD 1217: $MD_CURRENT_FILTER_3_BANDWIDTH (bandwidth speed set-
point filter 3)
• Modify MD 1216: $MD_CURRENT_FILTER_3_SUPPR_FREQ (suppression fre-
quency current setpoint filter 3)
• Modify MD 1220: $MD_CURRENT_FILTER_4_BANDWIDTH (bandwidth speed set-
point filter 4)
• Modify MD 1219: $MD_CURRENT_FILTER_4_SUPPR_FREQ (suppression fre-
quency current setpoint filter 4)
1 Alarms