Siemens SINUMERIK 840D Series Diagnostics Manual page 287

Hide thumbs Also See for SINUMERIK 840D Series:
Table of Contents

Advertisement

11.02
Reactions:
Remedy:
Program Continuation:
20080
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20085
Parameters:
Definitions:
Reactions:
Remedy:
Program Continuation:
20090
Parameters:
Definitions:
Reactions:
 Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
- Alarm display.
- Interface signals are set.
- Local alarm reaction.
- NC Start disable in this channel.
- NC Stop on alarm.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
Specify correct target position (reversal position, end position).
Clear alarm with the RESET key. Restart part program
Channel %1 axis %2 no handwheel assigned for overlaid motion
%1 = Channel number
%2 = Axis number
No handwheel has been assigned for this specified axis after handwheel overlay has
been started in automatic mode. If the axis identifier is missing in the alarm with active
velocity overlay FD > 0, then the 1st geometry axis has not been defined in the NC chan-
nel. In this case the block is executed without handwheel control.
- Alarm display.
If handwheel control is required, a handwheel must be activated.
Alarm display showing cause of alarm disappears. No further operator action
Channel %1 contour handwheel: traverse direction or overtravel of beginning of
block not allowed
%1 = Channel number
Travel takes place on the path with the contour handwheel in the opposite direction to the
programmed travel direction and the starting point of the path has been reached at the
start of the block.
- Alarm display.
Turn the contour handwheel in the opposite direction.
Alarm display showing cause of alarm disappears. No further operator action
Axis %1 travel to fixed stop not possible. Check programming and axis data.
%1 = Axis name, spindle number
1. The "Traverse against fixed stop" function has been programmed with FXS[AX]=1 but
the axis does not (yet) support this. Check MD 37000. This function is not available for
gantry axes and simulated axes.
2. On selection, no movement was programmed for axis AX. AX is a machine axis identi-
fier.
3. It is always necessary to program a traversing movement in the selection block for the
axis/spindle for which the "Traverse against fixed stop" function is activated.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
- Mode group not ready.
- Channel not ready.
- If the axis is a single axis when this alarm is triggered, the alarm is only effective for this
axis (not effective for e.g. the channel or mode group)
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
1 Alarms
1-287

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840di seriesSinumerik 810d seriesSinumerik 840dSinumerik 840diSinumerik 810dSinumerik 840de ... Show all

Table of Contents