LCE–Last Serial Command Error
Displays the last serial command error.
Commands
Command
Description
LCE?
Returns the last serial command error. (Read-only)
LDI–Laser Diode Information
Displays the information of each laser diode bank including its voltage and temperature.
Commands
Command
Description
LDI+LDV1
Displays the current voltage status for laser diode 1. (Read-only)
LDI+LDV2
Displays the current voltage status for laser diode 2. (Read-only)
LDI+LDV3
Displays the current voltage status for laser diode 3. (Read-only)
LDI+LDV4
Displays the current voltage status for laser diode 4. (Read-only)
LDI+LDV5
Displays the current voltage status for laser diode 5. (Read-only)
LDI+BT1
Displays the temperature status for bank 1. (Read-only)
LDI+BT2
Displays the temperature status for bank 2. (Read-only)
Examples
Display the information for the laser diode bank 1:
(LDI+LD01)
LHO–Lens Shift Horizontal
Adjusts the horizontal lens offset.
Commands
Command
Description
LHO <position>
Adjusts the horizontal location of the lens.
GS Series 599 Serial Commands Technical Reference
020-102403-02 Rev. 1 (04-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
Values
Values
n = Increases horizontal location of the lens
by one
p = Decreases horizontal location of the lens
by one