Shu-Shutter; Sif-Secondary Source Information - Christie 599 GS Series Technical Reference

Serial commands
Table of Contents

Advertisement

SHU–Shutter
Opens and closes the shutter.
Commands
Command
Description
SHU?
Gets the state of the shutter.
SHU <0 | 1>
Opens or closes the shutter.
Examples
Get the state of the shutter:
(SHU?)
Result:
(SHU!0)
Indicates the shutter is open.
Open the shutter:
(SHU 0)
Close the shutter:
(SHU 1)
SIF–Secondary Source Information
Displays the current settings for the picture-in-picture/picture-by-picture image input.
Returns secondary source information in read-only mode.
Commands
Command
Description
SIF+ACTS?
Returns the active source.
SIF+SGFT?
Returns the signal format.
SIF+APRT?
Returns the aspect ratio.
SIF+RESL?
Returns the resolution.
SIF+VREF?
Returns vertical refresh information.
SIF+HREF?
Returns horizontal refresh information.
SIF+PIXC?
Returns the pixel clock settings.
SIF+SYNC?
Returns the sync type.
GS Series 599 Serial Commands Technical Reference
020-102403-02 Rev. 1 (04-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
0 = Opens the shutter
1 = Closes the shutter (Default)
Values