Remote Button
SHUTTER
EXIT
UP
RIGHT
DOWN
LEFT
LCB–Lens Motor Calibration
Calibrates all of the lens motors.
Commands
Command
Description
LCB+HOME 1
Moves the lens to the center and horizontal
and vertical position. Zoom and focus are
not affected.
LCB+LOCK <0 | 1>
Locks the zoom, focus, and horizontal and
vertical lens motors.
Examples
Center the lens:
(LCB+HOME 1)
Lock the zoom, focus, and horizontal and vertical lens motors:
(LCB+LOCK 1)
LCE–Last Serial Command Error
Displays the last serial command error.
This command is read only.
Commands
Command
Description
LCE?
Returns the last serial command error.
GS Series Serial API Commands Technical Reference
020-000814-01 Rev. 1 (06-2015)
Key Code (Decimal)
2
20
38
41
42
39
Remote Button
LENS V-DOWN
PIP/POP
SIZE
LAYOUT
SWAP
Values
0 = Allows movement of the zoom, focus,
and horizontal and vertical lens motors
(Default)
1 = Locks the zoom, focus, and horizontal
and vertical lens motors
Values
Serial API commands
Key Code (Decimal)
17
15
67
68
43