Cca-Color Matching - Christie 599 GS Series Technical Reference

Serial commands
Table of Contents

Advertisement

(BSS 1)
CCA–Color Matching
Defines the hue of each primary color component (red, green, blue, and white).
Commands
Command
Description
CCA+MTRA <0 | 1>
Enables or disables meter adjustments.
CCA+MTTP <0 | 1>
Enables or disables the automatic test
patterns for manual adjustment.
CCA+RDMI <value>
Specifies the red intensity.
CCA+RDMX <value>
Specifies the x coordinate for red.
CCA+RDMY <value>
Specifies the y coordinate for red.
CCA+GNMI <value>
Specifies the green intensity.
CCA+GNMX <value>
Specifies the x coordinate for green.
CCA+GNMY <value>
Specifies the y coordinate for green.
CCA+BLMI <value>
Specifies the blue intensity.
CCA+BLMX <value>
Specifies the x coordinate for blue.
CCA+BLMY <value>
Specifies the y coordinate for blue.
CCA+WHMI <value>
Specifies the white intensity.
CCA+WHMX <value> Specifies the x coordinate for white.
CCA+WHMY <value> Specifies the y coordinate for white.
CCA+RDDG <value>
Specifies the red gain.
GS Series 599 Serial Commands Technical Reference
020-102403-02 Rev. 1 (04-2017)
Copyright
2017 Christie Digital Systems USA Inc. All rights reserved.
©
Serial API commands
Values
0 = Turns off meter adjustments (Default)
1 = Turns on meter adjustments
0 = Turns off automatic test patterns
1 = Turns on automatic test patterns
(Default)
100 to 10000
453 (Default)
0.300 t0 0.700
0.633 (Default)
0.300 to 0.500
0.356 (Default)
100 to 10000
2137 (Default)
0.300 to 0.400
0.352 (Default)
0.400 to 0.700
0.572 (Default)
100 to 10000
239 (Default)
0.100 to 0.300
0.140 (Default)
0.030 to 0.400
0.093 (Default)
100 to 10000
9219 (Default)
0.200 to 0.400
0.331 (Default)
0.200 to 0.400
0.380 (Default)
0.200 to 1.000
15