Mitsubishi Melsec-Q Series User Manual page 548

Hide thumbs Also See for Melsec-Q Series:
Table of Contents

Advertisement

Number
Name
Meaning
SD774
PID limit setting
0: With limit
to
(for complete
1: Without limit
SD775
derivative)
PID limit setting
0: With limit
SD774
(for complete
1: Without limit
derivative)
b0 to b14:
0: Do not
refresh
Refresh
1: Refresh
processing
b15 bit
selection when
0: Communication
SD778
the COM/
with CPU
CCOM
module is
instruction is
executed
executed
1: Communication
withCPU
module is
nonexecuted
*9: Function version is B or later.
*11: The module whose first 5 digits of serial No. is "04012" or later.
*12: The module whose first 5 digits of serial No. is "07032" or later.
*13: The module whose first 5 digits of serial No. is "09012" or later.
12 - 253
Table12.40 Special register
Explanation
• Specify the limit of each PID loop as shown below.
b15
SD774
Loop16
to
SD775
Loop32
to
• Specify the limit of each PID loop as shown below.
to
b15
b8
Loop8
SD774
• Selects whether or not the data is refreshed when the COM instruction is
executed.
• Designation of SD778 is made valid when SM775 turns ON.
b15
b14
to
b5
b4
b3
0
SD778
0/1
0/1 0/1 0/1
• Refresh between multiple CPUs by COM instruction is performed under
the following occasion.
Receiving operation from other device: b4 of SD778(refresh in the CPU
shared memory) is turned to 1.
Sending operation from host CPU : b15 of SD778(communication with
peripheral device is executed/nonexecuted) is turned to 0.
• Selects whether or not the data is refreshed when the COM instruction is
executed.
• Designation of SD778 is made valid when SM775 turns ON.
b15
b14
b6
b5
b4
b3
to
0/1
0
0/1
0/1
0/1 0/1
SD778
• Refresh between multiple CPUs by COM instruction is performed under
the following occasion.
Receiving operation from other device: b4 of SD778(refresh in the CPU
shared memory) is turned to 1.
Sending operation from host CPU : b15 of SD778(communication with
peripheral device is executed/nonexecuted) is turned to 0.
• When b2 (refresh of the CC-Link IE controller network and
MELSECNET/H) of SD778 is 1, the CC-Link IE controller network and
MELSECNET/H perform refresh.
Therefore, if there are many refresh points, processing time for the COM
instruction will be extended.
(When Set)
b1
b0
Loop2
Loop1
Loop18
Loop17
to
b7
b1
b0
Loop2
Loop1
to
b2
b1
b0
0/1
0/1
I/O refresh
CC-Link refresh
MELSECNET/H
refresh
Automatic refresh of
intelligent function
modules
Automatic refresh of
CPU shared memory
(Fixed to "0" for
Redundant CPU)
Execution/non-
execution of
communication with
CPU module
b2
b1
b0
0/1
0/1
I/O refresh
CC-Link refresh
CC-Link IE controller
network or
MELSECNET/H refresh
Automatic refresh of
intelligent function
modules
Reading input/output
from group outside
multiple CPU system
Auto refresh using the
multiple CPU high speed
transmission area of
multiple CPU system
Execution/non-
execution of
communication with
CPU module
Corres-
Set by
ponding
Corresponding
ACPU
CPU
D9
Qn(H)
U
New
QnPRH
QnU
U
New
Q00J/Q00/Q01
Q00J/Q00/Q01
U
New
Qn(H)
Qn(H)
U
New
QnPH
QnPRH
*9
*9
*11
*13
*12