Mitsubishi Melsec-Q Series User Manual page 546

Hide thumbs Also See for Melsec-Q Series:
Table of Contents

Advertisement

Number
Name
Meaning
Backup execution
Backup
SD691
status display
execution status
(Percentage)
Factor of error
Restoration error
SD692
occurred in the
factor
restoration
Restoration
Current restoration
SD693
status
status
Restoration
Restoration
execution status
SD694
execution status
display
(Percentage)
Specification of
Specification of
writing to stan-
writing to standard
SD695
dard ROM
ROM instruction
instruction count
count
Available
SD696
Available memory
memory in
in memory card
SD697
memory card
SD698
Backup data
Backup data
capacity
capacity
SD699
*1: The module whose first 5 digits of serial No. is "10102" or later. (Except the Q00UJCPU, Q00UCPU, and Q01UCPU)
12 - 251
Explanation
• Displays the execution status of data backup to the memory card in
percentage (0 to 100%).
• "0" is set when the backup starts.
Stores the factor of an error that occurred in the restoration.
Each error factor is as follows:
800
: The CPU module model name is not matched.
H
801
: The file password is set only for the restoration destination data or is
H
not matched.
810
: The verified backup data file is not matched or the backup data read
H
failed.
Stores the current restoration execution status.
Each error factor is as follows:
0 : Before restoration start
1 : Restoration in execution
2 : Restoration completed
FF: Restoration error
Sets "0" (Before restoring), however, when the restoration is completed
only during the automatic restoration.
• Displays the execution status of restoration to the CPU module in
percentage (0 to 100%).
• "0" is set before the restoration.
Sets "0" (Before restoring), however, when the restoration is completed
only during the automatic restoration.
• Specifies the maximum number of executions of the writing to standard
ROM instruction (SP.DEVST) to write to the standard ROM per day.
• When the number of executions of the writing to standard ROM
instruction exceeds the number of times set by SD695, "OPERATION
ERROR" (error code: 4113) occurs.
• The setting range for SD695 is 1 to 32767. If 0 or value outside the
range is set, "OPERATION ERROR" (error code: 4113) occurs at
execution of the writing to standard ROM instruction.
Stores the available memory in memory card. (Stores the value in 32-bit
binary.)
Stores the backup data capacity. (Stores the value in 32-bit binary.)
Corres-
Set by
ponding
Corresponding
ACPU
(When Set)
D9
S (Status
New
change)
S (Error
New
occurrence)
S (Status
New
change)
S (Status
New
change)
U
New
S (Backup in
New
operation)
CPU
*1
QnU
QnU
*1
QnU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents