Voltage in terminals of AB (GB1 and GB2) in proper operating charge system should be
much the same and correspond to generator voltage and make from 13 to 15
.15.2.4 Simultaneously all working lamps fail to operate on the cab roof, lamps of
7
the sign "Road-train", air conditioner, dome lamp, window wiper and rear window washer.
) Check fuse 80A operability on the fuse block F3. In case of failure, replace the fuse.
b) If fuse 80A operates properly, check the operability of the electric circuit from the fuse
block F3 to the fuse block F2.

7.15.3 Search and elimination of failures in engine start-up system

Starter makes low rpm (if winter operating conditions are observed)
7.15.3.1
) Correct possible unfastening or corrosion of power circuit terminals:
- on accumulator batteries;
- on clutch coupling case ("minus" circuit);
- on power circuit breaker QS1;
- on starter terminals and starter fixture.
b) Test state of charge, level and electrolyte density and state of accumulator bat-
teries (terminal and cap surface cleanness). Charge and carry out maintenance services of
AB if necessary.
c) If after abovementioned operations have been carried out starter starting rpm
have not changed, contact your dealer for starter repair.
Solenoid starter switch responds (when it is switched on token sound can
7.15.3.2
be heard), but starter does not rotate:
) If indicating lamp on instrument board operates normally, contact your dealer for
starter repair;
b) If indicating lamp on instrument board deaden significantly, then perform opera-
tions, described in cl. 7.15.3.1.
7.15.3.3 Starter won't start.
The following types of failures and troubleshooting methods:
1. Check starter for operability by means of connection with indicating lamp (indicat-
ing lamp for starter test should be 24V) to "ground" by one wire and by another wire one at
a time to:
- load-bearing terminal;
- solenoid starter switch terminal (by turning starter switch key to position "II" with range se-
lector lever set in neutral position).
If in both cases indicating lamp:
- lights – contact your dealer for starter repair;
- won`t light or lights in one of the abovementioned cases make repairs on electri-
cal power supply circuits and start control.
Test starter interlock switch S 3 operation with transmission range engaged.
2.
Interlock switch have follower in the form of rod with normally closed contacts. The
interlock switch is located in speed control mechanism and put into circuit (brown wire) be-
tween coil ( 9.2) starter relay 9 (located in SU) and "ground". When transmission range
is engaged breaker contacts will unclose, locking engine start. When transmission range
selector lever is in neutral position, the control follower won't have an effect on switch
plunger, its contacts are closed ensuring "ground" of coil of starter relay 9 and possibility
of engine start-up.
To test breaker S 3 operability perform the following:
- remove wires holding block from terminals of switch;
- switch on multimeter in "ohmmeter" mode by connecting it to breaker S 3 con-
tact;