(10) Cut off the wire tie binding the cables in the Base side.
(11) Remove the Arm Top Cover.
(12) Remove the User Plate.
(13) Disconnect 10 connectors on the Arm side.
(14) Disconnect two connectors inside the Base.
(15) Disconnect the D-sub cable, air tube, and Ethernet cable (RJ45) from the User Plate.
NOTE
(16) Remove the two ground wires from the User Plate.
NOTE
(17) Be careful not to lose the cable clamp, protection sheet, and fixed screws.
(18) The nut secures the cable duct fittings to the User
(19) Rotate the cable duct fittings to remove the nut that
LS10-B Rev.6
Remove the seven ground wires that secured on the mount
base.
Be careful not to lose the spacer which holding the ground
wires.
For details, refer to Maintenance: 3.1 Arm Top Cover.
For details, refer to Maintenance: 3.5 User Plate.
Connectors: X22, X33,X42, X43, X44, X51, BR, X221, X231, X241
Connectors: X41, X211
Mounting screws for the D-sub cable are very small. Be sure to keep the screws.
Press the ring on the fittings to pull out the air tube. (ø6×2, ø4×1)
Remember the cable layout for reconnecting the disconnected parts after replacement.
Unscrew the cable clamp binding the cables in the Arm side and remove it and
protection sheet.
Plate. Rotate the nut to remove it, and pull out the
cables from the User Plate.
secures to the Base, and pull out the cables from the
Base.