Event
Trace Contents
Level
No.
7109
User task boundary
Caution
In executing user
error
task
710C User task division error
Caution
In executing user
task
710D User task BCD
Caution
In executing user
conversion error
task
710E User task table
Caution
In executing user
operation error
task
710F
User task encode error
Caution
In executing user
task
7112
User task non-numeric
Caution
In executing user
input
task
7113
User task overflow error Caution
In executing user
task
7124
Transmission buffer get
Caution
error
7125
Transmission buffer
Caution
release error
7126
FROM inside user
Caution
Initial diagnosis
information error
7134
EA download area
Caution
unregistered
7135
Backup request
Caution
interrupted
7136
Restore request
Caution
interrupted
Table D-1 Error Trace (2 / 5)
Timing
Exec
Remarks
Continued
Access is made over the
variable boundary.
Continued
Value 0 was used in
division.
Continued
BCD conversion
exceeded the data area.
Continued
An error occurred in
processing LP_PARA,
PV_DATA or other table.
Continued
A limit end error occurred
in encoding.
Continued
A non-numeric value was
input in executing a real
instruction.
Continued
Operation result
exceeded the limits for
that numeric type.
Continued
Continued
Continued
Error in user information
saved inside FROM
Continued
EA No. non-existing in EA
table was downloaded.
Continued
Continued
Task
Address
Aux1
Aux2
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
IP
IP
IR
(absolute)
(relative)
Status
Status
Status
Status
Status
Status
Aux3
Cause
Maintenance
LD, ST, contact, coil and
Download after correcting
other symbols have
the points of modified
variable names of
structure, index, etc. that
modified structure,
are outside the variable
array, index, etc., and
boundary.
the points indicated
thereby are over the
variable boundary.
The divisor is 0 in
Download after correcting
division instruction.
the user task to avoid the
divisor 0.
In integer-to-BCD
Download after correcting
conversion, a value
the user task so that the
exceeding the limits
input value will not exceed
(INT type: 9999; DINT
the limits.
type: 99999999) was
input.
Addresses specified in
Download after checking
LP-PARA, PV_DATA,
and correcting the
or other table are
tablespecified addresses.
outside the range.
In executing a real
Download after correcting
instruction, a value
the user task to avoid
unable to be processed,
nonnumeric inputs.
for example, +/-1#INF,
was input.
In executing an INT
Download after correcting
addition instruction, a
the user task so that the
value exceeding the
input value will not exceed
limits, for example,
the limits.
3267+1, was input.
User information is not
Download user
saved in FROM
information and execute
because of no FROM
FROM write (save user
write, or the user
information in FROM).
information in FROM is
destroyed.