Appendix E Details of Variables
Item name
Output hardware
address 1
Output hardware
address 2
Output hardware
address 3
Input inversion 1
Input inversion 2
Input inversion 3
Alarm 1
Alarm 2
Alarm 3
Lamp display 1
Lamp display 2
Lamp display 3
Output inversion 1
Output inversion 2
Output inversion 3
Button display 1
Button display 2
Button display 3
Button returned
output 1
Button returned
output 2
Button returned
output 3
E
Button 1 pressed
output 1
Button 1 pressed
output 2
Button 1 pressed
output 3
170
Abbr.
OA1
The output point of process signal is registered in the form of
00_01_01_MM_PP. Digital output points are registered. The
relation between this output and 3-point pushbutton is determined
OA2
by the registered content in the output table.
• MM indicates module number (00 to 15). 2 digits are required.
OA3
• P indicates point number (1 to 32).
Point Numbers for Each Module
Point
I/O module
SDO01
SLP03,SLP04
The address is displayed in 8 digits in hexadecimal number on the
Side display.
Example: In the case of MM = 14 and P = 2, 00000E02
INV1
This is used to set whether the signal of input point should be
inverted to light the Lamp 1, 2 or 3.
INV2
• Invert / Not invert
INV3
INA1
This is used to set whether Lamp 1, 2 or 3 should be used as
alarm condition when the lamp lights.
INA2
• ON: Used as alarm / OFF: Not used as alarm
INV3
UI1
This is used to set whether the lamp should be used as the
function of illuminated pushbutton 1, 2 or 3.
UI2
• Display / Non-display
UI3
ONV1
This is used to set whether the value after output table processing
should be inverted or not to send it to output point 1, 2 or 3.
ONV2
• Invert / Not invert
ONV3
UO1
This is used to set whether the button should be used as the
function of illuminated pushbutton 1, 2 or 3.
UO2
• Display / Non-display
UO3
DA01
The operation for output of each point when pushbutton is
returned can be selected from the following:
• None (No processing) / S (Output is set) / R (Output is set) T
DA02
(Output is inverted)
DA03
DA11
The operation for output of each point when Button 1 is pressed
can be selected from the following:
• None (No processing) / S (Output is set) / R (Output is set) T
DA12
(Output is inverted)
DA13
Description
⋅⋅⋅⋅⋅⋅⋅
1
2
3
4
⋅⋅⋅⋅⋅⋅⋅
DO1 DO2 DO3 DO4
⋅⋅⋅⋅⋅⋅⋅
DO1 DO2 DO3
Model 1000 Loop Controller L1 LC511,512 User's Manual
Data type
DSP
[unit]
DWORD
31
32
DO31 DO32
BOOL
BOOL
BOOL
BOOL
BOOL
DWORD
DWORD