Mounting Instructions
ProfiDAT
compact
®
Data Transmission System
Program 0515
ATTENTION!
3.6 Unsuitable environmental conditions
The conductor rail system must not be installed and not be operated under these environmental conditions (see also section 2.5,
section 2.8.4 and section 3):
In environments containing chemical substances or gases that can potentially permanently damage the conductor rail's materials
(corrosion) or drastically impact on the insulation
In ambient air that contains solvent vapors or aromatic compounds
In ambient air that contains flammable or explosive gases or dusts
In dusty environments
Outside closed rooms
Relative humidity above 50 % rel. at +40° C
In close proximity to splashing water
In environments that require a higher protection class than IP 2X
MAL0515-0001c-EN
www.conductix.com
Faults due to incorrect operating conditions!
Operating conditions outside the specified range can lead to malfunctions due to short
circuits, premature aging and damage to electrical and mechanical components.
Important parameters are:
Dust and deposits
Humidity/condensation
Cold/hot temperatures
Corrosion
Chemical substances
The conductor rail system must be switched off if the operating conditions are no longer within
the permissible range described above.
The conductor rail system must be switched off if it is wet or dirty. Dry or clean according to
the instructions (see section 11 for special maintenance instructions for conductor rail
systems).
Take the relevant measures to restore suitable operating conditions.