4 - 8
Error! Reference source not found. Error! Reference source not found.
Step 5:
Press and hold the menu button while turning on the bar feed.
You may release the menu button when the following screen appears.
Step 6:
Wait until the PLC run light indictor goes from a flashing to a solid state. (This may take a few seconds.)
Step 7:
Once the light is in a solid state, flip the RUN/STOP switch to STOP position. (The run light indicator will turn off)
Step 8:
A password is required at this point using the number buttons on the pendant enter 3; 1; 4; 1; 5.
Step 9:
There are 4 menu choices on this screen, press the F3 key for PLC Fault.
QUICK LOAD SERVO S3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUICK LOAD SERVO S3 and is the answer not in the manual?

Questions and answers

tom,
March 18, 2025

LNS BARFEEDER sps no response , how do i fix this error

1 comments:
Mr. Anderson
March 18, 2025

The SPS No Response alarm on the QUICK LOAD SERVO S3 occurs due to a communication problem between the remote control station and the LNS PLC. To fix this error:

1. Check the connectors between the PLC and the remote control station inside the cross piece to ensure they are correctly attached.
2. Verify continuity between the PLC and the remote control station.

These steps help restore proper communication and resolve the error.

This answer is automatically generated