Diameter Change Control Device Is Out of Sync

ATTENTION!
THE DIAMETER CHANGE
CONTROL DEVICE IS
OUT OF SYNC!
MOVE LOADING CHANNEL
TO ITS UPPER
POSITION AND PROCEED
TO ITS RECALIBRATION
**REFER TO MANUAL**
Description:
The Diameter Change Control Device Is Out Of Sync alarm occurs if there is a mechanical problem after entering a new diameter in
the Part Setup menu.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm. Press the
function key on the remote control station corresponding to the Manual Mode icon. Press the function key on the remote control
station corresponding to the V-channel Upper Position icon. Follow the
Chapter 2: Common Issues.
QUICK LOAD SERVO S3
Chapter 1: Alarms
Calibration of the Loading Table pg. 3-31
procedure in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUICK LOAD SERVO S3 and is the answer not in the manual?

Questions and answers

tom,
March 18, 2025

LNS BARFEEDER sps no response , how do i fix this error

1 comments:
Mr. Anderson
March 18, 2025

The SPS No Response alarm on the QUICK LOAD SERVO S3 occurs due to a communication problem between the remote control station and the LNS PLC. To fix this error:

1. Check the connectors between the PLC and the remote control station inside the cross piece to ensure they are correctly attached.
2. Verify continuity between the PLC and the remote control station.

These steps help restore proper communication and resolve the error.