3 - 4
Step 3:
Carefully loosen the 16 screws located in the slots on the base of the unit. This will allow the unit to be adjusted up and
down.
Step 4:
Using the central jackscrew and the hexagonal tube supplied with the bar feed; adjust the unit so that the pusher is centered
up and down at the back of the spindle. Make sure that the unit raises or lowers uniformly.
QUICK LOAD SERVO S3
Central jackscrew
Pusher should be centered
vertically with the spindle.
Chapter 3: Procedures
Hexagonal tube

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QUICK LOAD SERVO S3 and is the answer not in the manual?

Questions and answers

tom,
March 18, 2025

LNS BARFEEDER sps no response , how do i fix this error

1 comments:
Mr. Anderson
March 18, 2025

The SPS No Response alarm on the QUICK LOAD SERVO S3 occurs due to a communication problem between the remote control station and the LNS PLC. To fix this error:

1. Check the connectors between the PLC and the remote control station inside the cross piece to ensure they are correctly attached.
2. Verify continuity between the PLC and the remote control station.

These steps help restore proper communication and resolve the error.