1 - 3 2

Door Lathe Open

DOOR LATHE OPEN!
CLOSE DOOR LATHE
TO RESUME OPERATIONS
Description:
The Door Lathe Open message occurs only on Guildemeister machines when the door of the lathe is opened. A separate input signal
(I0.5) is added as a safety precaution for the operator. When the lathe door is open the bar feed generates this message preventing
the bar feeder from pushing.
Solution:
Press the HELP key on the remote control station. Press the F4 key (Page Down icon) twice.
Case
Input
Remote Pendant
1
Bit 5 = 1
2
Bit 5 = 0
QUICK LOAD SERVO S3
MODULE 0
76543210
100000
MODULE 0
Alarm needs to be cleared. Press the STOP key on the
76543210
remote control station to clear the message and reset
the alarm.
0
Solution
Close the lathe door.
If the door was opened during a part feed out, the
alarm needs to be cleared. Press the STOP key on
the remote control station to clear the message and
reset the alarm. Restart the bar feed and lathe in
automatic production.