Code
415.3
0415.3 - CYLINDER 4, SHORTED TO HIGH
SOURCE (SERVICE TOOL FAULT CODE
XXX)
415.4
0415.4 - CYLINDER 4, SHORTED TO LOW
SOURCE (SERVICE TOOL FAULT CODE
XXX)
416.2
0416.2 - CYLINDER 2, DATA INCORRECT
(SERVICE TOOL FAULT CODE XXX)
416.3
0416.3 - CYLINDER 2, SHORTED TO HIGH
SOURCE (SERVICE TOOL FAULT CODE
XXX)
416.4
0416.4 - CYLINDER 2, SHORTED TO LOW
SOURCE (SERVICE TOOL FAULT CODE
XXX)
417.2
0417.2 - CYLINDER 6, DATA INCORRECT
(SERVICE TOOL FAULT CODE XXX)
417.3
0417.3 - CYLINDER 6, SHORTED TO HIGH
SOURCE (SERVICE TOOL FAULT CODE
XXX)
417.4
0417.4 - CYLINDER 6, SHORTED TO LOW
SOURCE (SERVICE TOOL FAULT CODE
XXX)
418.2
0418.2 - CYLINDER 3, DATA INCORRECT
(SERVICE TOOL FAULT CODE XXX)
418.3
0418.3 - CYLINDER 3, SHORTED TO HIGH
SOURCE (SERVICE TOOL FAULT CODE
XXX)
418.4
0418.4 - CYLINDER 3, SHORTED TO LOW
SOURCE (SERVICE TOOL FAULT CODE
XXX)
419.2
0419.2 - CYLINDER 5, DATA INCORRECT
(SERVICE TOOL FAULT CODE XXX)
419.3
0419.3 - CYLINDER 5, SHORTED TO HIGH
SOURCE (SERVICE TOOL FAULT CODE
XXX)
419.4
0419.4 - CYLINDER 5, SHORTED TO LOW
SOURCE (SERVICE TOOL FAULT CODE
XXX)
420.2
0420.2 - BATTERY VOLTAGE, DATA
INCORRECT (SERVICE TOOL FAULT
CODE 146)
420.3
0420.3 - BATTERY VOLTAGE, SHORTED
TO HIGH SOURCE (SERVICE TOOL FAULT
CODE 146)
420.3
0420.3 - BATTERY VOLTAGE, SHORTED
TO HIGH SOURCE (SERVICE TOOL FAULT
CODE 146)
420.3
0420.3 - BATTERY VOLTAGE, SHORTED
TO HIGH SOURCE (SERVICE TOOL FAULT
CODE 146)
420.4
0420.4 - BATTERY VOLTAGE, SHORTED
TO LOW SOURCE (SERVICE TOOL FAULT
CODE 146)
435.2
0435.2 - AMBIENT PRESSURE (PHY),
DATA INCORRECT (SERVICE TOOL
FAULT CODE 16)
DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM
Description
A.50.A / 14
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Battery - Incorrect value (A.30.A.83 - G.30.C.10)
Battery - Short circuit to B+ (A.30.A.83 - G.30.B.54)
Battery - Short circuit to B+ (A.30.A.83 - G.30.B.54)
Battery - Short circuit to B+ (A.30.A.83 - G.30.B.54)
Battery - Short circuit to ground (A.30.A.83 -
G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)