E0084-14-Voting Conflicts Found Special Instructions (A.50.A.93 -
G.30.E.11)
E0084-14 - Voting Conflicts Found Special Instructions
Cause:
A data location has data which is different in all of the voting modules.
Possible failure modes:
1.
Vehicle configuration and calibration information corrupted.
Solution:
1.
When installing a new or replacement CCM module into the vehicle, the other modules will supply current config-
uration information to this module based on true democratic voting rules. If all reporting modules have different
configuration data, there is no majority consensus as to what the values should be. As a result, configuration
information will not be written to the new or replacement module, and the configuration data will remain un-
changed (and therefore different) in all modules. If this error message appears, review machine configurations
to make sure that they are correct.Re-write configuration data using the electronic service tool (EST).
A.