New Holland CX720 Repair Manual page 1409

Hide thumbs Also See for CX720:
Table of Contents

Advertisement

Code
435.3
0435.3 - AMBIENT PRESSURE (PHY),
SHORTED TO HIGH SOURCE (SERVICE
TOOL FAULT CODE 16)
435.4
0435.4 - AMBIENT PRESSURE (PHY),
SHORTED TO LOW SOURCE (SERVICE
TOOL FAULT CODE 16)
436.2
0436.2 - SHUT-OFF UNDER VOLTAGE,
DATA INCORRECT (SERVICE TOOL
FAULT CODE 164)
436.3
0436.3 - SHUT-OFF UNDER VOLTAGE,
SHORTED TO HIGH SOURCE (SERVICE
TOOL FAULT CODE 164)
436.4
0436.4 - SHUT-OFF UNDER VOLTAGE,
SHORTED TO LOW SOURCE (SERVICE
TOOL FAULT CODE 164)
437.2
0437.2 - SHUT-OFF EXCESS VOLTAGE,
DATA INCORRECT (SERVICE TOOL
FAULT CODE 163)
437.3
0437.3 - SHUT-OFF EXCESS VOLTAGE,
SHORTED TO HIGH SOURCE (SERVICE
TOOL FAULT CODE 163)
437.4
0437.4 - SHUT-OFF EXCESS VOLTAGE,
SHORTED TO LOW SOURCE (SERVICE
TOOL FAULT CODE 163)
438.2
0438.2 - SHUT-OFF MONITOR MODULE,
DATA INCORRECT (SERVICE TOOL
FAULT CODE 160)
438.3
0438.3 - SHUT-OFF MONITOR MODULE,
SHORTED TO HIGH SOURCE (SERVICE
TOOL FAULT CODE 160)
438.4
0438.4 - SHUT-OFF MONITOR MODULE,
SHORTED TO LOW SOURCE (SERVICE
TOOL FAULT CODE 160)
439.2
0439.2 - SHUT-OFF PATH MES0, DATA
INCORRECT (SERVICE TOOL FAULT
CODE 162)
439.3
0439.3 - SHUT-OFF PATH MES0, SHORTED
TO HIGH SOURCE (SERVICE TOOL FAULT
CODE 162)
439.4
0439.4 - SHUT-OFF PATH MES0, SHORTED
TO LOW SOURCE (SERVICE TOOL FAULT
CODE 162)
440.2
0440.2 - SHUT-OFF PATH MES1, DATA
INCORRECT (SERVICE TOOL FAULT
CODE 161)
440.3
0440.3 - SHUT-OFF PATH MES1, SHORTED
TO HIGH SOURCE (SERVICE TOOL FAULT
CODE 161)
440.4
0440.4 - SHUT-OFF PATH MES1, SHORTED
TO LOW SOURCE (SERVICE TOOL FAULT
CODE 161)
441.2
0441.2 - BOOST AIR TEMP (PHY), DATA
INCORRECT (SERVICE TOOL FAULT
CODE 17)
441.3
0441.3 - BOOST AIR TEMP (PHY),
SHORTED TO HIGH SOURCE (SERVICE
TOOL FAULT CODE 17)
DISTRIBUTION SYSTEMS - ELECTRONIC SYSTEM
Description
A.50.A / 15
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Injection control - Incorrect value (B.20.A.92 -
G.30.C.10)
Injection control - Short circuit to B+ (B.20.A.92 -
G.30.B.54)
Injection control - Short circuit to ground
(B.20.A.92 - G.30.B.53)
Sensing system Air temperature sensor - Incorrect
value (B.30.A.95.80 - G.30.C.10)
Sensing system Air temperature sensor - Short
circuit to B+ (B.30.A.95.80 - G.30.B.54)
2 4/7/2006
Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cx740Cx760Cx780Cx820Cx840Cx860 ... Show all

Table of Contents